Specifications
|
Physical |
|
|
Dimensions |
100mm x 70mm (4.0" x 2.75") |
|
Weight |
70g (2.5oz) |
|
Environmental |
|
|
Operating temperature |
-10°C (14°F) to 55°C (131°F) UL/ULC*: -10°C (14°F) to 49°C (120.2°F) |
|
Operating humidity |
5% (0°C or 32°F) to 95% (40°C or 104°F) UL/ULC*: 5% (0°C or 32°F) to 93% (32°C or 90°F) |
|
Electrical |
|
|
Power consumption |
50mA at 12VDC all inputs terminated (UL/ULC*: 40mA at 12VDC input with full load) |
|
Power supply |
12VDC to 14VDC |
|
Inputs |
2 analog or digital multi EOL monitored. Optional for 6 without using Wiegand input. (UL/ULC*: 10K) |
|
Outputs |
2 relay NO/NC 1A at 24VDC 6 O/C outputs 1x solid state relay 0V to 24V AC/DC at 1A |
|
Tamper |
1x digital input for connecting tamper signal |
|
Communication |
|
|
Dual flash memory |
Firmware updated from the main controller without losing door operation. (UL/ULC*: NA) |
|
Wiegand |
2x Data0/Data1 signals with optional pull-up |
|
Miscellaneous |
|
|
Degraded mode support |
Continuous door transactions if disconnected from the main controller 1000 users; 1000 transactions; 24 hours (UL/ULC*: NA) |
*UL/ULC = UL: UL 294, UL 2610 / ULC: CAN/ULC 60839-11-1, ULC S304, ULC/ORD C1076